Our double glazed uPVC windows have been thoroughly tested for compliance in Australia and have achieved one of the highest energy rating for a standard Double glazed Residential product. Our Double Glazed Window & Door products perform better than some of the competitions triple glazed windows. See for yourself at the Australian Window Associations WERS Website
Certification & Testing
Nu-Eco Windows – Standard Glass Types
Our Certifications
4mm Monolithic Glass
| Window ID | Outer Glass | Gap | Inner Glass | Cooling Stars | Heating Stars | Cool % | Heat % | U Value | SHGC | T-vis | AI |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NUE-003-16 | 4mm Clear | 20mm Argon | 4mm Clear Low E Plus | 68% | 76% | 1.5 | 0.33 | 0.44 | 0.1 | ||
| NUE-003-17 | 4mm Clear | 20mm Argon | 4mm Clear Low E Plus | 75% | 70% | 1.5 | 0.23 | 0.27 | 0.1 | ||
| NUE-003-18 | 4mm Clear | 20mm Argon | 4mm Clear Low E Plus | 74% | 71% | 1.5 | 0.24 | 0.39 | 0.1 | ||
| NUE-003-05 | UK glass - 4mm Clear | 20mm Argon | UK glass - 4mm Clear Low E | 64% | 80% | 1.5 | 0.39 | 0.44 | 0.1 |
5mm Monolithic Glass
| Window ID | Outer Glass | Gap | Inner Glass | Cooling Stars | Heating Stars | Cool % | Heat % | U Value | SHGC | T-vis | AI |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NUE-003-021 | 5mm Clear | 18mm Argon | 5mm Clear Low E Plus | 69% | 76% | 1.4 | 0.32 | 0.43 | 0.1 | ||
| NUE-003-22 | 5mm Grey | 18mm Argon | 5mm Clear Low E Plus | 77% | 68% | 1.5 | 0.21 | 0.23 | 0.1 |
6mm Monolithic Glass
| Window ID | Outer Glass | Gap | Inner Glass | Cooling Stars | Heating Stars | Cool % | Heat % | U Value | SHGC | T-vis | AI |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NUE-003-23 | 6mm Clear | 16mm Argon | 6mm Clear Low E Plus | 69% | 76% | 1.4 | 0.32 | 0.43 | 0.1 | ||
| NUE-003-24 | 6mm Grey | 16mm Argon | 6mm Clear Low E Plus | 78% | 67% | 1.4 | 0.19 | 0.20 | 0.1 | ||
| NUE-003-25 | 6mm Green | 16mm Argon | 6mm Clear Low E Plus | 77% | 69% | 1.4 | 0.21 | 0.36 | 0.1 | ||
| NUE-003-26 | 6mm Clear | 16mm Argon | 6mm Clear Low E Max | 67% | 69% | 1.4 | 0.21 | 0.35 | 0.1 | ||
| NUE-003-27 | 6mm Grey | 16mm Argon | 6mm Clear Low E Max | 83% | 63% | 1.4 | 0.13 | 0.17 | 0.1 |
Nu-Eco Windows – Window Testing
Testing shows compliance with Australian Standards AS2047, exceeding the requirements for a standard residential Window. Results show that our windows are rated to an N4 (Non-Cyclonic),C2 (Cyclonic) rating, with no water penetration at 600pa of pressure , way above the 150pa requirement in the standard. Our Multi-point locking system limited Air infiltration to 0.1 Ltrs/second, again way below the 5.0Ltr/Second in the standard.


Test Results
Deflection Test
| Component | Pressure | Deflection / Span Ratio |
|---|---|---|
Coupler Mullion | +950 Pa -1000 Pa | 1 / 250 1 / 252 |
Transom | +950 Pa -1000 Pa | 1 / 1754 1 / 1056 |
Sash Stile | +950 Pa -1000 Pa | 1 / 1165 1 / 955 |
Air Infiltration Test
| Air Leakage Recorded ((L/s.m2)) | Pressure Applied (Pa) | |||
|---|---|---|---|---|
| Condition | +75 | +150 | -75 | -150 |
| Chamber & Sample (A) | 0.1 | 0.1 | -0.1 | -0.1 |
| Chamber (sample taped) (B) | NR | NR | NR | NR |
| Sample (A-B) | 0.1 | 0.1 | -0.1 | -0.1 |
Water Penetration Test, 600 Pa
No water penetration was observed during the test.
Ultimate Strength Test: +2700 Pa & -2700 Pa
No sign of collapse was observed at either test pressure.
Conclusion
Housing Ratings
| Position on House | Non-exposed | Exposed |
|---|---|---|
| General | ||
| Corner Window |
Reidential and Commercial Building Ratings
+950 Pa and -1000 Pa
+2700 Pa and -2700 Pa
Air Infiltration Level: Low
(+0.1 and -0.1 L/s.m2)
Maximum water Penetration Resistance Pressure: 600 Pa
Distribution Info


Certification Details
Our Window Profiles Have Been Tested in Australia’s Harshest Environment


Conclusion
Nu-Eco Windows – UV Testing
Tested at Allunga Exposure Laboratory and testing facility in Townsville, QLD.
Nu-Eco’s frames have been independently tested in Australia’s harshest environment (when it comes to UV exposure) and have proven to exceed the international Standard ASTM DTS4726, as well as meeting the Australian uPVC Window Alliance’s code of conduct policy.
UV Exposure Testing
- Profiles subjected to minimum of 15,000 MJ/m2 UV radiation
Strength Testing
- Charpy text conducted before and after exposure
- Ensures strength and rigidity for Australian conditions
Extended In-House Testing Since 2013
Taking it one step further, we have been conducting our own in-house testing since September 2013. A number of uPVC samples were placed on the roof of our factory facing North to maximise exposure to the sun’s harmful rays.
We currently have data from the Bureau of Meteorology suggesting that our profiles have absorbed almost double the amount of solar radiation required by the standards, with outstanding results.
We placed control samples in storage to compare against the exposed samples shown in the images.
Certification Documents
AS 2047 Compliance Certificate
Exposure chart below show 35,789 MJ/M2 of Exposure
| Days in the month | 31 | 28 | 31 | 30 | 31 | 30 | 31 | 31 | 30 | 31 | 30 | 31 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Year | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | Annual |
| 2013 | 13.1 | 15.3 | 18.6 | 22.8 | 14.7 | ||||||||
| 2014 | 25.2 | 20.7 | 14.6 | 9.1 | 7.4 | 5.6 | 6.3 | 9.5 | 13.9 | 17.9 | 22.7 | 23.9 | 14.7 |
| 2015 | 22.4 | 19.5 | 16.4 | 10.8 | 7.3 | 6.7 | 6.7 | 8.8 | 14.2 | 19.9 | 20.4 | 26.9 | 15.0 |
| 2016 | 21.5 | 21.1 | 14.4 | 12.3 | 8.3 | 6.6 | 7.4 | 10.0 | 12.9 | 16.7 | 19.8 | 23.2 | 14.5 |
| 2017 | 23.1 | 20.4 | 16.7 | 10.7 | 8.1 | 7.1 | 8.2 | 9.8 | 13.1 | 18.3 | 22.5 | 22.3 | 15.0 |
| 2018 | 23.8 | 20.6 | 16.4 | 10.8 | 7.4 | 7.4 | 8.0 | 9.8 | 13.4 | 17.8 | 21.4 | 24 | 15.0 |
| 2019 | 32.1 | 28.7 | 23.2 | 17.0 | 11.7 | 9.3 | 10.6 | 15.7 | 19.6 | 27.2 | 31 | 31.7 | 21.5 |
| 2020 | 31.9 | 28.5 | 22.0 | 15.8 | 11.9 | ||||||||
Total radiation (TR) | 159.5 |
123.7
| 180.0 | 86.5 | 62.1 | 36.1 | 39.8 | 53.6 | 74.2 | 117.8 | 118 | 128.8 | |
Total (TR* Days) | 5580 | 4466 | 3834 | 2595 | 1925 | 1083 | 1223 | 1661 | 2226 | 3651 | 3540 | 3992 | |
| Total Exposure to May 2020 | 35789 |
Exposed samples vs control samples
Samples have absorbed more than double the required solar radiation exposure required by the Standard. They are compared to control samples that have never seen the sun.
The results show very little difference after more than five years of direct exposure. Under normal conditions, window profiles are generally exposed to far less radiation due to shading and positioning.